n1849778
by Rabi Gurung

Move Schneider Electric EcoStruxure Control Expert License From One Computer To Next Offline

October 14, 2021 No comment(s) Control Expert, Engineering, Schneider Electric, TechTalk Account, Acivate, Activation ID, Activation Request XML, Control, Control Expert, Creation, EcoStruxure, ecostruxure control expert, EcoStruxure Control Expert license, Electric, Expert, INTERNET, License Activation, License Manager, Modicon, No Internet, Offline, Pro, Return, Schneider, Schneider Electric, Schneider Electric License Manager, Software Licensing Web Portal, Unity, Use another activation method, Web Portal, Web User Management, World Wide Web, WUM, WWW, XML
Facebook
Twitter
Google+
LinkedIn
Pinterest

Learn how to move Schneider Electric Control Expert license from one computer to another computer where all the computers are offline.

Essentially there are 3 ways to activate and/or move the EcoStruxure Control Expert license.

  • Web Portal. This is a self service function (aka Direct). It requires you to generate a Request XML file which needs to be uploaded to the Schneider Electric Web Portal, and in return the web portal will provide you with a response XML file.
  • Mobile phone. This is a self service function (aka Direct). You have to provide your cell phone number and a code will be provided to you via cell phone.
  • Call Schneider Electric Technical Support. This ia an assisted service from Schneider Electric.

The intent of this article to demonstrate the Web Portal technique.

For a Web Portal license transfer technique, you will need access to the Internet in some form as you will have to upload a Request XML file to the Schneider Electric License Portal and the portal will respond with a respond license XML file.

For the ease of discussion, Computer A currently has the EcoStruxure Control Expert license and have Internet connection as well. And Computer B does not have EcoStruxure Control Expert license and does not have Internet connection. This is a perfect scenario in any oil and gas scenario, where you have an engineering workstation with Internet connection and is isolated from the World Wide Web (WWW)

The YouTube video demonstrates how to move the EcoStruxure Control Expert license from Computer A to Computer B.

Here are the steps.

1) From Computer A, return the EcoStruxure Control Expert license using the Schneider Electric License Manager. I use the word “Return” as you need to return the license back to the Schneider Electric License Web Portal.
Xybernetics Schneider Electric Control Expert Return EcoStruxure Control Expert license

2) From the Computer B Generate the Request License XML file using the Schneider Electric License Manager. You will need and EcoStruxure Control Expert Activation ID.
Xybernetics Schneider Electric Control Expert Request License XML Activate

Xybernetics Schneider Electric Control Expert Request License XML Activation Method
Xybernetics Schneider Electric Control Expert Web Portal

3) Move the Request License XML file to Computer A (with Internet access).

4) Upload the Request License XML file to the Schneider Electric License server.
Software Licensing Web Portal
https://www.se.com/ww/sites/corporate/en/support/software-licensing/landing-page
OR
https://se.com/licensing
Select “Process License Request File” as shown below.
Xybernetics Schneider Electric Control Expert Process License Request File

Xybernetics Schneider Electric Control Expert Request License Process File
Xybernetics Schneider Electric Control Expert Upload Request License XML File
Xybernetics Schneider Electric Control Expert Register Later

5) You will be given an opportunity to download the Response License XML file.
Xybernetics Schneider Electric Control Expert Download Response License XML File

6) Move the Response License XML file (that you downloaded to Computer B).

7) From Computer B, load the Response License XML file using the Schneider Electric License Manager.

Xybernetics Schneider Electric Control Expert Load Response License XML File Using Schneider Electric License Manager

I hope that help!!!

Reference

  • Control Expert Activation Using Web Portal
  • Web User Management (WUM) Account Creation
  • Software Licensing Web Portal
  • I don’t have an internet connection and I would like to activate my EcoStruxure Control Expert license
n1849778
About the Rabi Gurung
I am a software developer in Calgary, Alberta, Canada with passion in getting my fingers in any new technology. I started software development when I was 10 years old and have never looked back. Now with well over 35 years of software development, I wanted to share some of these key knowledge with the people of the world in the wide web.
Categories
  • 3D Printing
  • 800xA
  • ABB
  • Acronis
  • Adobe After Effects
  • Allen Bradley
  • Android
  • Apache
  • App Store
  • Apple
  • Arduino
  • ASP.NET
  • Atmos
  • AVEVA
  • Azure DevOps
  • Barnett
  • Batch
  • Bedrock Automation
  • Beijer
  • blender
  • C
  • C#.Net
  • Catalina
  • CISCO
  • ClearSCADA
  • CompactLogix
  • Control Expert
  • ControlLogix
  • cURL
  • Debian
  • Docker
  • Eaton Xpert Meter 2000 PMX 2000
  • EIP3170
  • Electronics
  • Engineering
  • Excel
  • FactoryLink
  • FactoryTalkView
  • FAST/TOOLS
  • FASTTOOLS
  • GIMP
  • Github
  • Google
  • Google Chrome
  • Google Cloud Console
  • Google Drive
  • Google Fit
  • Google Map
  • Google Play
  • Harmony
  • Hitfilm
  • Horner
  • HTML
  • IIS
  • Infi90
  • iOS
  • iX Developer
  • JavaScript
  • Kepware
  • Kubernetes
  • LAMP
  • Lets Encrypt
  • Linux
  • Logic Designer
  • macOS
  • Matrikon
  • MB3170
  • Microhard
  • MicroLogix
  • Microsoft
  • Miscellaneous
  • MOXA
  • Mozilla Firefox
  • MySQL
  • Networking
  • NodeJS
  • Notepad++
  • OAuth2
  • OBS
  • Office 365
  • OSX
  • Outlook
  • PanelView
  • Particle
  • PHP
  • PIP
  • Pipeline
  • PlantPax
  • PLC-5
  • Postman
  • Powerpoint
  • Programming
  • Prosoft
  • ProTalk Link
  • Python
  • Rancher
  • Raspberry Pi
  • RDP
  • RealFlo
  • Redlion
  • Redlion
  • Redmine
  • RegEx
  • Remote Connection
  • Repo
  • Resource Configurator
  • Router
  • Samsung
  • SCADAPack
  • Schneider Electric
  • SCP
  • Selenium
  • SLC500
  • SQL
  • ssh
  • STARDOM
  • Stratix
  • Studio 5000
  • Sublime
  • TeamViewer
  • TechTalk
  • Telepace
  • TightVNC
  • Tindercad
  • Twitter
  • Ubuntu
  • Uncategorized
  • Unity Pro
  • Unity3d
  • VBA
  • VBA
  • Visual Studio
  • VMWare
  • vSphere
  • Well Test
  • Windows
  • WinSCP
  • Wonderware
  • Word
  • Xamarin
  • XCode
  • XMAL
  • Yokogawa
  • YouTube
  • Zip
Latest Posts
  • Enable Project Navigator and Project Toolbox In CScape For Horner PLC September 6, 2023
  • Setup multiple monitor display in Yokogawa FAST/TOOL September 6, 2023
  • Download And Upload Horner PLC Program September 2, 2023
Recent Comments
    Tags
    800xA ABB Allen Bradley Android Apple Bedrock Automation Beijer C#.Net CompactLogix Control Expert ControlLogix Eaton Xpert Meter 2000 PMX 2000 Engineering Excel FactoryTalkView FASTTOOLS Harmony Infi90 MicroLogix Microsoft Miscellaneous MOXA PanelView Particle PLC-5 Programming Prosoft RealFlo Redlion Redlion SCADAPack Schneider Electric SLC500 STARDOM TechTalk Telepace Ubuntu Unity Pro VMWare Windows Wonderware Xamarin XCode XMAL Yokogawa
    Calendar
    September 2025
    M T W T F S S
    1234567
    891011121314
    15161718192021
    22232425262728
    2930  
    « Sep    
    Xybernetics © 2025.
    • Facebook
    • Twitter
    • Youtube
    • Pinterest