General |
CPU | Toshiba S1X643034 |
Core Processor | ARM920T |
Speed | 400 MHz |
RAM | 64MB |
Solid State Drive Space | 512MB |
Supply Voltage | 6VDC - 15VDC |
Supply Current | 13mA - 500mA |
Power Consumption | 1.2W - 16.2W (depending on number of USB port usage, 2.5W per USB) |
Operating Temperature | -40°C to 70°C |
Hazardous Location | Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations. Temperature Code T4 CSA certified to the req of CSA Std. C22.2, No 142, 213 ANSI/ISA 12.12.01-2000 for Hazardous Locations Certification UL 508 (Industrial Control Equipment) |
Flow Computer |
Number of concurrent meter runs | 10 |
Flow algorithms | AGA-3 (1992/2000) AGA-7 V-Cone Wafer Cone |
Compression calculations | AGA-8 (1992) |
Energy calculation | GPA2172 AGA-5 |
Calculation speed | Once per second |
Event Log | 40 days of audit trails (configurable) |
Reports | Daily Report Monthly Report Meter Report (As Found/As Left) Snapshot Report (On Demand by User) |
Standards and compliance tested | American Gas Association (AGA) American Petroleum institute (API) 21.1 Alberta Energy and Utilities Board (AEUB) Directive 17 |
Data Access Tool |
Configuration | Microsoft Internet Explorer 7.0 or higher Firefox 14 or higher Safari 4 or higher Or any internet browser |
Calculated Data | Microsoft Internet Explorer 7.0 or higher Firefox 14 or higher Safari 4 or higher Or any internet browser |
Event Log | Microsoft Internet Explorer 7.0 or higher Firefox 14 or higher Safari 4 or higher Or any internet browser |
Reports | Microsoft Internet Explorer 7.0 or higher Firefox 14 or higher Safari 4 or higher Or any internet browser |
Event and Report File Format | Comma Separated Values (CSV) |
Required Operating System (OS) | Any OS |
Additional Information | User can configure, monitor and access (import/export) flow calculation data and configuration parameters remotely (from their laptop, operating room, HMI server room or engineering workstations). |
Miscellaneous |
Security | Login required to configure flow parameters. Event log tracks user change(s) |
Time Sync Capability | Able to configure/sync time though the web configuration tool |
Maintenance Mode | Maintenance mode is available for the purpose of testing and loop checking |
Communication Port |
Ethernet Port (RJ45, 10/100BaseT) | 1 |
RS-485 (configurable) | 6 |
RS-232 (configurable) | 6 |
Wi-Fi | Allows for 255 mobile devices (e.g. laptop, smart phone and tablet) connections |
Communication Protocol |
Protocols | Modbus TCP (Ethernet) Modbus RTU (serial RS232 and/or RS485) |
Baudrate | 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 |
Web Services |
Services | Hypertext Transfer Protocol (XyberHTTP) Secure File Transfer Protocol (XyberSFTP) Dynamic Host Configuration Protocol (XyberDHCP) |
Physical Dimension |
Size | 3.4"(86.36mm) wide, 5.5"(139.70mm) deep, 1.33"(33.78mm) high |
Application |
Flow measurement in wellhead |
Pipeline leak detection |
Energy consumption measurement |
Gas and liquid totalisation |